Wood Fired Cooling

YES! It is HERE! Wood Fired Cooling! What?

You CAN COOL your building with a wood Fired Boiler! 

Off-Grid COOLING & AIR CONDITIONING

Have you ever wondered how off-grid COOLING & AIR CONDITIONING works?

Are you looking for a wood stove for cooling your house in the summer?  

I have read several articles about a Wood fired boiler to power air conditioner/chiller and one on a Wood Stove to power an air conditioner/chiller.

Did you search for Heating and Cooling with Sustainable Biomass Energy
and an affordable absorption chiller for wood fired air conditioning.

Wood-fired air conditioning WORKS!

You wouldn't think so but it is proven!

ROCKET STOVE

And there is even a page out there on Rocket Stove Air Conditioning! We build the BIGGEST ROCKET STOVE in the world!

Doesn't make sense? Read on to find out how to use our Hyprotherm Outdoor Wood Stove or Coal Boiler for cooling your home, shop or business!

INTRODUCING the Yazaki water-fired SINGLE-EFFECT chillers (with cooling capacities of 5 to 100 tons of refrigeration) produce chilled water for cooling, while chiller-heaters (with cooling capacities of 10 to 30 tons of refrigeration) produce chilled water, but also can provide hot water for heating in comfort air conditioning applications. The absorption cycle is energized by a heat medium (hot water) ranging from 158°F to 203°F from a Hyprotherm Wood or Coal Boiler, an industrial process, cogeneration system, solar energy, or other heat source. The condenser circuit is water cooled through a cooling tower or ground loop.

wood fired air conditioning

Visit them at http://www.yazakienergy.com/waterfired.htm

We have partnered with Yazaki Energy Systems, Inc and Yazaki Water-Fired Chillers as the OEM supplier to the public and all outdoor wood furnace boiler manufacturers to give you the FIRST WOOD FUELED COOLING SYSTEM! 

When the heat medium inlet temperature exceeds 154.4°F, the cooling unit springs into action. Max cooling is with 190.4F; very doable with out 75%+ efficient wood boiler!

Power Consumption is a little as 48 Watts, single phase for their smallest unit and 210 Watts (3 phase) for the next size up, on up to 670 Watts for their 600 MBTUh model and even LESS for their BIGGEST 1200 MBTUh unit!  VERY MINIMAL compared to a typical power hungry A/C unit!  That is the rating on the Yazaki unit alone and does not include external pumps or fan motors.  

Much like an auto air conditioning system, this uses an orifice; where refrigerant liquid accumulates in the condenser sump and then passes through an orifice into the evaporator.

Features and Benefits

•

• Ideal for heating when used in a two-pipe system 
with properly sized water coils. (WFC-SH models only)

 

• Mode and Enable/Disable condition can be selected remotely.

 

••Only a 30-minute changeover delay between cooling and heating modes. (WFC-SH models only)

 

• The absorption cycle is energized by hot water. 

• This hot water can be from any source such as a wood boiler
cogeneration, solar, or
any waste heat source as long as it can be provided

to the chiller or chiller-heater at a temperature between 158°F to  203°F, which the Hyprotherm boilers will easily do!

 

• Extended capacities available when supplied with cooling water colder than design standard of 87.8°F 
(WFC-M designstandard 85°F) and/or heat medium warmer than design standard of 190.4°F (WFC-M design standard 194°F)

.

• Faster cold start-up time (as quick as 90 seconds) than similar chillers with flooded generators.


• Working fluids of lithium bromide and water operate

under a vacuum at all times and are safe, odorless and non-toxic.

 

• Only one rotating part: the hermetically sealed solution pump.

 

• Vacuum vessel fully hermetically sealed at the 
factory for a level of vacuum integrity that is unmatched in the industry.

No field welding necessary.

 

• Helps to prevent crystallization by utilizing a 
solution pump and gravity drain-back design.

 

• Chilled and hot water outlet temperatures controlled by a built-in microprocessor with outputs to 
control a 3-way heat
medium bypass valve, all relevant pumps, and even 
the cooling tower fan (if so desired). All valves and pumps are

field-supplied. Alternatively, the valves are available as a factory-supplied 
but field-installed option.

 

• Built-in logic will shut down the unit under abnormally high heat medium and/or cooling water 
temperatures to help prevent crystallization and other service-related issues.

 

• Proprietary solution and inhibitor blends ELIMINATE

the need for regular chemical analysis of working

fluids within the unit, resulting in much simpler regular 
maintenance
when compared with most other manufacturers.

 

• All chillers and chiller-heaters are supplied with

UL50E Type 3R cabinets that are suitable for indoor

or outdoor installation without modification. See Wood Fired Cooling Brochure for sizes

 

• Factory charged and run tested. Solution balancing

done at the factory so that it does not need to be

done in the field at startup potentially eliminating DAYS of 
necessary commissioning time when compared with 
other manufacturers.

 

UL Listed as a unit for USA and Canada



Contact WNC Stoves today on 5 TON to 100 TON units to heat your building. See how much money YOU can save!

LOTS of valuable information and charts in their brochure; DOWNLOAD BROCHURE HERE!

Call Ben at 828-683-8055 9AM - 9PM 6 days a week!


Wood Boiler HOME
|
BENEFITS | FAQ | PICTURES | INSTALLATION | PURCHASE/PRICES | SHIPPING  

CONTACT US 6 DAYS a WEEK